Comparative Analysis Of The Structural Response of A G+8 Storied Building With Varying Shear Wall Placements Using ETABS.
View/ Open
Date
2026-01-10Author
Hamim, Abu Darda
Al-Amin, Md.
Rasid, Md. Mamunur
Mondol, Hridoy
Metadata
Show full item recordAbstract
This study presents a comparative analysis of three structural building models subjected to
seismic and wind load conditions. The objective is to evaluate their performance with respect
to interstorey drift limits, total sway limitations, and overall structural efficiency in accordance
with applicable code requirements. Each model was analyzed using ETABS to obtain lateral
displacement and drift responses under EQx, EQy, Wx, and Wy load cases. The results show
that Option -2 provides superior performance, satisfying both drift and sway criteria for all load
combinations. In contrast, Option -1 fails to meet the drift and sway requirements in the EQx
direction, indicating comparatively low lateral stiffness. Option -3 performs better than Option -1 but fails the sway limit in the EQx case, demonstrating the need for additional stiffness
enhancement. Among the three, Option -2 not only ensures structural safety and full code
compliance but also proves to be the most economical solution, offering optimized material
usage while maintaining adequate lateral resistance. This study concludes that Option -2
represents the most effective and efficient structural configuration for the building under the
evaluated loading conditions.