• Login
    View Item 
    •   SUSpace Home
    • Faculty of Science and Engineering
    • Department of Civil Engineering
    • 2020 - 2023
    • View Item
    •   SUSpace Home
    • Faculty of Science and Engineering
    • Department of Civil Engineering
    • 2020 - 2023
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Comparison Of Wind Load And Seismic Effect On Law Rise And High Rise Multistory Structures According To BNBC 2020 By Using Etads

    Thumbnail
    View/Open
    BCE-220739.pdf (3.983Mb)
    Date
    2022-08-26
    Author
    Al. Amin Khan, Al. Amin
    Md. Abdus Shahenn, Md. Abdus
    Md. Rasaduzzamn Shabuz, Md. Rasaduzzamn
    Mejanur Rahman, Mejanur
    Sajel Ahmed, Sajel
    Metadata
    Show full item record
    Abstract
    The Bangladesh National Building Code (BNBC) specifies and regulates the general specifications for structural, architecture and design parameters in Bangladesh. In the last three decades, Civil Engineering techniques, knowledge, and materials as well as design parameters have been modified as per requirement. Therefore, BNBC 2020 was written to reflect the transition. In this study, a systematic and parametric structural analysis of a Six-story(Low rise) and Ten-Story(High rise) residential building was analyzed (ETABS 19.0 software) by using BNBC 2020.In this project lateral load (Earthquake and Wind) affects structural analysis and design of high-rise infrastructure for Dhaka city. The decision-making parameters for structural analysis and design are tremor and wind forces, story drift, wind and seismic shear and base shear for seismic forces according to BNBC 2020. In this study, the maximum story displacement of low rise to high rise multistory structure is 121.84%, 287.05%, 219.72% and 450% for load EQX, EQY, WX and WY respectively. And the maximum story drift of low rise to high rise multistory structure is 60.44%, 66.58%, 113.08%, and 100.488% for load EQX, EQY, WX and WY respectively. The comparison of the aforesaid design parameters is depicted graphically, and relevant tables are presented in this research article. In comparison of wind load and seismic effect on low rise and high-rise multistory structures, the requirements of BNBC 2020 usually result in a less cost-effective design with a higher safety margin. v
    URI
    http://suspace.su.edu.bd/handle/123456789/839
    Collections
    • 2020 - 2023 [238]

    Copyright © 2022-2025 Library Home | Sonargaon University
    Contact Us | Send Feedback
     

     

    Browse

    All of SUSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Copyright © 2022-2025 Library Home | Sonargaon University
    Contact Us | Send Feedback